Electrocardiograph ECG 300G Products Description
ECG600G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for "Lead off" and "Lack of paper", multi-language interface, case database management.
Our ECG 300G has been designed with the latest technology and features, and we believe it is one of the best products available in the market. In this product introduction, we will explore the features and benefits of our Electrocardiograph ECG 300G and explain why it is the best choice for merchants who want to offer their customers an exceptional heart monitoring product.

why choose us ?
- 
	1. Accurate and reliable heart monitoring: Our ECG 300G provides accurate and reliable heart monitoring, making it an invaluable tool for healthcare professionals who need to evaluate patients' heart health. 2. Improved patient outcomes: By using our ECG 300G, healthcare professionals can make better and more informed decisions about their patients' heart health, leading to improved patient outcomes. 3. Time-saving technology: Our ECG 300G has advanced signal processing technology that eliminates interference and noise, saving healthcare professionals valuable time that they can spend on other important tasks. 4. Enhanced portability: Our ECG 300G is portable and lightweight, making it easy to move from one location to another. This enhances its usability in hospitals, clinics, and other healthcare settings. 5. Increased patient satisfaction: By using our ECG 300G, healthcare professionals can provide their patients with a high-quality heart monitoring experience that is accurate, reliable, and easy to understand. 
Electrocardiograph ECG 300G Meter Feature

1.Paper compartment cover
Keep the paper compartment closed, hold the printing paper
2.Display screen
Display patient's ECG and related information
3.Button area
Control the operations of the device, and enter information.
4.Cover switch
To open or close the paper compartment cover.

5.Lead cable interface
Connect with lead cables.
6.USB interface
Communicate with the computer. The ECG data and analysis result can be transmitted to a computer, by using the computer, many functions can be achieved, such as archiving, managing, and analyzing ECG data, which facilitates clinical research, organization teaching and training, as well as program upgrade, case export and connection with

7.Equipotential terminal
Connect with the potential equalization conductor.
8.Input socket
Connect with AC power cord.

1.Startup indicator
It lights in green after turning on the device.
2.Power status indicator
Green indicates that the AC power supply is used. At this time, there is no battery in the device or the battery is full. Red and green two colors indicate that the battery is being charged.
3.MENU
Menu button
4.MODE
When the device in sampling interface, use MODE button to select the print mode.
5. 1mV
Calibration button
6. PRINT
Print the sampled ECG waveform or end the printing.
7.Direction button
Up button
8.Direction button
Right button
9.SET
System menu and confirm.
10.Direction button
Down button
11. Direction button
Left button
12. FILTER
Set the filter mode.
13. SPEED
Change the ECG recording speed
14. SEN
Adjust the sensitivity manually.
15. ON/OFF
When the device is turned on, short press this button, it will prompt whether to shut down the device, long press this button to turn off the device.
Data description
| Customized data | Description | 
| Total recording number | 549 | 
| Race | Yellow race | 
| Coverage of age, gender | Aged from 17 to 87, average age 57.23, standard deviation 21.32; 326 male, average age 55.54, standard deviation 19.81; 223 female, average age 59.70, standard deviation 22.63. | 
| Sampling data | 12-lead ECG data (I, Ⅱ, Ⅲ, AVR, AVL, AVF, V1, V2, V3, V4, V5, V6), sampling frequency of each channel: 1kHz, amplitude quantization: 2.4μV/LSB. | 
| Remark | The interpretation conclusion of customized data is determined by the physician diagnostic results of cardiac catheterization and ultrasonic examination, and the ECG judgment result in physical examination, the details as blow: 1) Normal ECG Determined by the diagnostic result that judged as normal in cardiac catheterization and ultrasonic examination, and the result that judged as normal in physical examination. 2) Atrium hypertrophy Determined by the diagnostic results of ultrasonic examination. 3) Myocardial infarction and myocardial ischemia Determined by the physician diagnostic results of cardiac catheterization. 4) Tachycardia, bradycardia, low voltage, axis Determined by the diagnostic results of ultrasonic examination. 5)Conduction block Determined by the physician diagnostic results of cardiac catheterization. The standard of normal population in the customized database: physical examination is normal, no heart disease or other diseases that may affect cardiac functions or shape. | 
Electrocardiograph ECG 300G Parking Data
| Dimension | 315 mm(L)×215 mm(W)×77 mm(H) | 
| Net Weight | 1.6 kg | 

Hot Tags: electrocardiograph ecg 300g, China electrocardiograph ecg 300g manufacturers, suppliers






 
   
    
  