| Introduction |
The POCT Reagents work with the HTY-100 Reader is a fluorescence immunoassay that quantifies the Inflammation Markers, Cardiac Markers,Tumor Markers ,Diabetic&Renal Injury Markers, Infectious Diseases, Hormon Markers and the others.
| Specifications |
Inflammation Markers
|
Cat.No |
Test Item |
Kit Size |
Diseases |
Specimen |
|
H611 |
CRP C-reactive Protein |
25T/Box |
Inflammation |
Whole blood Serum Plasma |
|
H612 |
PCT Procalcitonin |
|||
|
H613 |
SAA Serum Amyliod A |
|||
|
H614 |
CRP/SAA Combo |
|||
|
H615 |
HB P Heparin-binding Protein |
Plasma |
||
|
H616 |
CCP IgG Cyclic Citrullinated Peptide IgG |
Whole blood Serum Plasma |
||
|
H617 |
RF/ASO/CRP Combo |
Serum |


Cardiac Markers
|
Cat.No |
Test Item |
Kit Size |
Diseases |
Specimen |
|
H621 |
cTnl Cardiac Troponin l |
25T/Box |
Mycocardial Infarction |
Whole blood Serum Plasma |
|
H622 |
CK-MB Creatine Kinase Muscle B |
25T/Box |
Mycocardial Infarction |
Whole blood Serum Plasma |
|
H623 |
Myoglovin |
25T/Box |
Mycocardial Infarction |
Whole blood Serum Plasma |
|
H624 |
D-dimer |
25T/Box |
Heart Failure |
Whole blood Plasma |
|
H625 |
NT-proBNP |
25T/Box |
Heart Failure |
Whole blood Serum Plasma |
|
H626 |
H-FABP |
25T/Box |
Mycocardial Infarction |
Whole blood Serum Plasma |
|
H627 |
CTNI/CK-MB/MYO Combo |
25T/Box |
Mycocardial Infarction |
Whole blood Serum Plasma |
|
H628 |
cTnl/NT-proBNP/D-D Combo |
25T/Box |
Heart Failure |
Whole blood Plasma |
|
H629 |
ST2 Growth Stimulation Expressed Gene 2 |
25T/Box |
Heart Failure |
Whole blood Serum Plasma |
|
H6291 |
NT-proBNP/ST2 Combo |
25T/Box |
Heart Failure |
Whole blood Serum Plasma |
|
H6292 |
Lp-PLA2 |
25T/Box |
Mycocardial Infarction |
Whole blood Serum Plasma |




Tumor Markers
|
Cat.No |
Test Item |
Kit Size |
Diseases |
Specimen |
|
H631 |
AFP Alpha-Fetoprotein |
25T/Box |
Liver Cancer |
Serum Plasma |
|
H632 |
T-PSA Total Prostate Specific Antigen |
25T/Box |
Prostate Cancer |
Serum Plasma |
|
H633 |
CEA Carcinoembryonic Antigen |
25T/Box |
Cancer |
Serum Plasma |
|
H634 |
PGI Pepsinogen I |
25T/Box |
Gastric Cancer |
Serum |
|
H635 |
PGI Pepsinogen II |
25T/Box |
Gastric Cancer |
Serum |
|
H636 |
FOB Fecal Occult Blood |
25T/Box |
Colorectal Cancer |
Feces |


Diabetic&Renal Injury Markers
|
Cat.No |
Test Item |
Kit Size |
Diseases |
Specimen |
|
H641 |
CysC Cystatin C |
25T/Box |
Diabetes Mellitus |
Serum Plasma |
|
H642 |
β2-MG β2-Microglobulin |
25T/Box |
Diabetes Mellitus |
Serum Plasma |
|
H643 |
NGAL |
25T/Box |
Diabetes Mellitus |
Serum |
|
H644 |
MAU Microalbumin |
25T/Box |
Diabetes Mellitus |
Urine |
|
H645 |
HbA1C |
25T/Box |
Diabetes Mellitus |
Whole Blood |



Infectious Diseases/Hormon Markers/Others
|
Cat.No |
Test Item |
Kit Size |
Diseases |
Specimen |
|
H651 |
MP-IgM Mycoplasma Pneumonoae IgM |
25T/Box |
Respiratory Disease |
Whole Blood Serum Plasma |
|
H652 |
MP IgG Mycoplasma Pneumonoae IgG |
25T/Box |
Respiratory Disease |
Whole Blood Serum Plasma |
|
H653 |
Cpn IgM Chlamydia Pneumonoae IgM |
25T/Box |
Respiratory Disease |
Whole Blood Serum Plasma |
|
H654 |
SARS-CoV-2 Neutralizing Antibody |
25T/Box |
Respiratory Disease |
Whole Blood Serum Plasma |
|
H661 |
Total β-HCG |
25T/Box |
Pregnancy |
Serum |
|
H662 |
T3 |
25T/Box |
Thyroid Function |
Serum |
|
H663 |
T4 |
25T/Box |
Thyroid Function |
Serum |
|
H664 |
TSH |
25T/Box |
Thyroid Function |
Serum |
|
H671 |
HB/TF Combo Hemoglobin/Transferrin Combo |
25T/Box |
Digestive Disease |
Feces |

| Applicable Reader |
The POCT Reagents should be read by Fluorescence Immunoassay Quantitative Analyzer
Model No.: HTY-100

| Sample Requirements |
Human serum, plasma, or whole blood can be used for the POCT Reagents.
Serum: Collect a certain amount of venous blood into a tube that does not contain an anticoagulant and place it at room temperature for blood coagulation; then, after fully centrifugation, take the serum for detection.
Plasma:Collect a certain amount of venous blood into a tube containing anticoagulant EDTA (other anticoagulants are not recommended) and place at room temperature for blood stratification; collect plasma after fully centrifugation for detection.
Whole Blood:Collect a certain amount of venous blood into an anticoagulant blood collection tube or a blood collection tube with EDTA anticoagulant (other anticoagulants are not recommended), and then mix for detection. The sample should be used right away.
| POCT Reagents Stability |
Serum or plasma samples can be kept at 2-8°C for 3 days. If you need to keep it for a longer period of time, freeze it at -20°C. Before detecting the samples, allow them to come to room temperature. Avoid freezing and thawing cycles.
Whole blood samples drawn via venipuncture should be tested right away.
Venous whole blood samples that have been stored for more than 7 days cannot be used for detection.
Limitations;
1. The POCT Reagent test results should be compared to other clinical and laboratory data. If the test results do not match the clinical symptoms, please try to confirm using other appropriate detection methods.
2. Collect blood using an EDTA-anticoagulated blood collection tube; no other anticoagulants should be used.
| Our Service |
Our strict quality control ensures the best service and quality, our aim is to make client 100% satisfied.Our goal is to let client set his heart at rest, and we will ensure the quality and amount to send the goods.
1. 7*24 after sales services
2. Professional factory
3. Rich experiences in export
4. Prompt response
5. ISO and CE certificate
6. Fast delivery
Why choose us?
- Our Immunoassay Analyzer products are designed with user safety in mind, ensuring that they are safe and easy to use.
- Our company will sincerely cooperate with every user with innovative technology, excellent quality and perfect service to create a better tomorrow hand in hand.
- We are a Chinese factory that specializes in high-quality Immunoassay Analyzer products and professional services.
- We expand the scope of value provision, provide high-quality, diversified products and services for a better life, and form a new strategic pattern of ecological synergy.
- Our Immunoassay Analyzer products are designed to be both accurate and efficient, saving our clients time and money in the lab.
- We always take protecting the environment and guarding the future as our own responsibility.
- Our company offers a wide range of Immunoassay Analyzers that are of the highest quality and are competitively priced.
- Creating and sharing sustainable value for all is in line with our dual commitment to economic development and social progress.
- We work closely with our customers to understand their requirements and provide customized solutions that meet their specific needs.
- We hope to prosper society and promote the development of human society by providing first-class POCT Reagents.
Hot Tags: poct reagents, China poct reagents manufacturers, suppliers