enLanguage
Home / Products / Details
video
HbA1c Analyzer

HbA1c Analyzer

HbA1c Analyzer can calculate the hemoglobin concentration in a blood sample. It can perform tests on samples as small as 1uL in a matter of minutes.

Add To Inquiry
Product Introduction

Products Description

The HbA1c Analyzer is intended for testing Glycohemogobin concentration as a tool for monitoring the risk of developing diabetes and managing diabetes. It is intended to be used in conjunction with the corresponding test strip.

There are a few pocket-sized HbA1c handheld analyzers on the market that can provide quick and easy HbA1c level measurements. These analyzers are intended for use by healthcare professionals and diabetics who need to monitor their HbA1c levels on a regular basis.

This system takes a small blood sample from a fingerstick and provides results in just 5 minutes. This analyzer is intended for use in medical facilities such as doctor's offices and clinics.

While these pocket-sized analyzers can provide quick and convenient HbA1c measurements, they are not as accurate as laboratory tests. It is always best to consult with a healthcare professional for interpretation of HbA1c results and to determine the best diabetes treatment plan.

 

Applying Buffer A

When the test strip is correctly inserted, the  Analyzer will prompt you to add three drops of buffer A. The corresponding buffer A symbol will begin to blink, and the characters '-2' and 'Add A' will be displayed. Indicating that the testing process has progressed to the second stage. At this point, add three continuous drops of buffer A to the buffer port (with voice prompt), as shown below:

product-1646-1350

After adding buffer A, the Analyzer will automatically detect buffer A. After buffer A has been detected, the system will enter into the 10 seconds countdown. lf buffer A is not add ed, a voice prompt will remind every 15 seconds.

Applying the blood sample
After a 10-second countdown, the HbA1c Analyzer will voice prompt you to add blood, and the blood sample symbol will begin blinking. '-3' and'Add bld' will be displayed, indicating that the testing process has progressed to the third step. Fill the sampler port with blood. Remember to keep the sampler in contact with the test strip for 3 seconds before removing it, as shown below:
product-2202-1690
After inserting a blood sample, the system will detect it automatically. After detecting a blood sample, the system begins a countdown of 130 seconds.
 
Applying buffer B
After the 130-second countdown, the HbA1c Analyzer will prompt you to add 2 drops of buffer B, and the corresponding buffer B symbol will blink, indicating that the testing process has entered the fourth step. At this point, add two continuous drops of buffer B vertically to the buffer port, as shown below:
product-2164-1610
After you add buffer B, the system will automatically detect it. The system enters the 130-second countdown after detecting buffer B.
 
Reading the result
At the end of the countdown, the analyzer emits a 'beep' sound and displays the test results. The test result can be displayed in either%NGSP or mmol/mol units. The type of units displayed is customizable by the customer.
The following result was displayed as%NGSP:
product-1036-419
Memory Function
The HbA1c analyzer can automatically store 1000 test results along with the test time and date. After the first 1000 test results have been saved, the earliest result will be removed from the new record.
 
Questions you may be interested in
1.When is the best time to have a HbA1c test?
HbA1c is a simple blood test that does not require fasting or any other special preparation and can be performed at any time of day.
2.What is the average HbA1c by age?

HbA1c reference values in age groups

The upper reference limit (URL) for HbA1c was 6.0% (42.1 mmol/mol) for people aged 20-39 years, increasing to 6.1% (43.2 mmol/mol) for people aged 40-59 years, and 6.5% (47.5 mmol/mol) for people aged 60 years.

3.What should I avoid before taking the HbA1c test?
The HbA1c test is a straightforward blood test. Your doctor or a pathology lab can draw the blood. There is no need to fast prior to the test; simply eat and drink as usual. Within 24 hours, the results should be available.
4.Why is my HbA1c high but my glucose normal?
Your A1C level can be affected by the amount of thyroid hormones in your bloodstream. This could cause the reading to fluctuate or give you incorrect results. Hypothyroidism, or low thyroid hormone levels, for example, has been linked to an elevated A1C level.
Products Advantage

HbA1c Analyzer is a revolutionary device that has been designed for the accurate measurement of glycated hemoglobin (HbA1c) levels in human blood. Produced by our company in China, this device has been specifically created to help medical professionals and other healthcare providers identify individuals at risk of developing diabetes, monitor patients with diabetes, and assess the effectiveness of diabetes treatment measures.

 

Features and Benefits:

There are several essential features that make it a must-have device for healthcare professionals.

baiduimg.jpg

Accurate Results

 The device uses high-precision technology that gives accurate and reliable results with a measurement range of 4.0% to 15.0%. It has been validated against international standards, guaranteeing accuracy and precision.

baiduimg.jpg

Fast and Efficient

The has a quick testing process that takes only5 minutes to complete from the start of the test till the display of results. This speed is unmatched by any other device in the market, and it saves considerable time for healthcare providers, allowing them to serve more patients in less time.

baiduimg.jpg

Portable

The device is compact, lightweight, and easy to carry, making it perfect for use in remote areas where access to medical facilities is limited.

baiduimg.jpg

Low Maintenance

The device requires minimal maintenance as it has minimal moving parts, which contribute to its high durability.

baiduimg.jpg

Easy to Use

The is user-friendly, and the results are displayed on the device's screen. It also has an auto-calibration feature, which ensures that the device is always calibrated accurately; this minimizes the possibility of measurement errors.

baiduimg.jpg

Economical

The is affordable, making it accessible to healthcare providers at various levels. It also has low running costs as it requires minimal maintenance, and it consumes low amounts of electricity.

Applications:

HbA1c Analyzer has a wide range of applications. It is especially useful in the following areas:

1. Diabetes Research and Management:

The device is useful in glycemic control research and monitoring HbA1c levels in patients with diabetes.

2. Screening for Diabetes:

The device is very useful for screening individuals at risk of developing diabetes. It helps in the early detection of the disease, enabling timely interventions and treatment measures.

3. Point of Care Testing:

The is ideal for point of care testing. It can be used in various healthcare settings, including clinics, hospitals, and even remote areas with minimal infrastructure.

4. Home-based Testing:

The device is user-friendly, and patients can use it from the comfort of their homes. This provides convenience and comfort to patients who need regular testing.

product-400-241
 

Our HbA1c Analyzer is an excellent device for healthcare providers who require accurate, speedy, and affordable HbA1c testing. Its efficient design and ease of use make it suitable for various healthcare settings, allowing healthcare providers to diagnose, screen, and manage diabetes with ease. We believe that this device will revolutionize the management of diabetes and make a significant difference in the lives of millions of individuals affected by diabetes worldwide.

 

Hot Tags: hba1c analyzer, China hba1c analyzer manufacturers, suppliers

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag