Products Description

The Blood Lipid Test Strip REF LPS-101 (Dry Chemistry) work with the Blood Lipid Analysis Meter or Dry Biochemical Analysis Meter to measure the lipid concentration in whole blood, plasma and serum.
For professional use or self-testing.
It is used determine the levels of Triglycerides, High Density Lipoprotein Cholesterol (HDL), and Total Cholesterol (TC) (TG). LDL and TC/HDL calculations are also done using it. Lipid measurements are used to diagnose metabolic abnormalities affecting lipids and lipoproteins, as well as to treat atherosclerotic coronary artery disease.
The Lipid Analyzer test the color intensity of the reaction end point at the wavelength of 620nm, the substance concentration is calculated by the reflection coefficient. When the test strip is LPS-101, with the following formula the concentration of low density lipoprotein cholesterol in (LDL) is calculated, the ratio of TC and HDL can also be calculated
Matching Analyzers
Dry Biochemical Analysis Meter
Fast and precise findings are guaranteed by the simple-to-use system, which comprises of a portable meter that measures the color and intensity of light reflected off a test strip's reagent area.
Results are provided via the Dry Biochemical Monitoring System. Up to 500 findings and records can be stored in the Dry Biochemical Analysis Meter. Battery charging is one way to use the meter.
Blood Lipid Analysis Meter
The analyzer uses blood lipid test strips (LPS-101, TCS-101, TGS-101, HLS-101) and operates on the basis of photochemistry.The test sample is added to the strip's sample area in its whole. Blood cells are either dissolved or filtered out during the quick infiltration process. The color shift that results from the substrate's reaction with chemicals and enzymes in the reaction layer is proportionate to the substance's concentration.
REAGENTS AND PERFORMANCE CHARACTERISTICS
|
Tests
|
Components
|
|
Total Cholesterol
|
Cholesterol Esterase>0.3U; Cholesterol Oxidase>0.2U; Peroxidase>0.6U; Ascorbate
Oxidase>0.1U; 4-aminoantipyrine>0.006mg
|
|
High Density
Lipoprotein
Cholesterol
|
Dextran Sulfate>0.1mg; Magnesium Chloride>0.1mg; Cholesterol Esterase>0.3U;
Cholesterol Oxidase>0.2U; Peroxidase>0.6U; Ascorbate Oxidase>0.1U;
4-aminoantipyrine>0.006mg
|
|
Triglycerides
|
Glycerol-3-Phosphate Oxidase>0.5U; Glycerol Kinase>0.5U; Lipoprotein Lipase>0.5U;
Peroxidase>0.6U; Ascorbate Oxidase>0.1U; ATP >0.2mg; 4-aminoantipyrine>0.006mg
|
Accuracy
| Specimen | Slope | Intercept | R | N |
|
Venous whole blood
|
0.9827
|
0.0955
|
0.993
|
100
|
| Specimen | Slope | Intercept | R | N |
|
Venous whole blood
|
0.9834
|
0.0092
|
0.994
|
100
|
| Specimen | Slope | Intercept | R | N |
|
Venous whole blood
|
0.9797
|
0.0336
|
0.996
|
100
|
● High Density Lipoprotein, Triglycerides, Calculated Low Density Lipoprotein, and CHOL/HDL Ratio are the analysis items.
It can distinguish between the single parameter and the three-in-one combination lipid device.
● CE Self-testing certified for Professional Usage and Self-testing
● Low Dose Micro Specimen: Just 35ul of whole blood (venous or capillary blood), plasma, or serum are required.
Specifications
| Measurement Range |
TC: 2.59-12.93 mmol/L(100-500mg/dL,1mmol/L=38.66mg/dL HDL:0.39-2.59mmol/L(15-100mg/dL,1mmol/L=38.66mg/dL) TG:0.51-7.34mmol/L(45-650mg/dL,1mmol/L=88.6mg/dL) |
| Specimen | Whole blood(capillary and venous), plasma and serum |
| Power Source | 1200mAh built-in lithium battery |
| Battery Endurance | After cycle charge 300 times, electric quantity reduce 30% |
| Units of Measurement | mmol/L, mg/dL |
| Memory | 500 records |
| Automatic Shut Off | 5 minutes after displaying results |
| Meter Size | 135*66*19mm(L*W*H) |
| Weight | 90g |
| Meter Storage Conditions | 0-55℃;≦90% RH |
| System Operating Conditions | 10-35℃; 0-90% RH; altitude 2000m |
| Test strip Storage Conditons | 2-30℃;≦90% RH |
| Warranty Period | 2 years |
| Meter Shelf Life | 4 years |
| Test Strip Shelf Life | 1 year |
Packing Data

| Box Size | 11*9*6 CM |
| Package Specification | test packed by aluminum pouch, 25pcs/box |
| Packing Quantity | 180 boxes/carton |
| Carton Size | 76.7*57*33.2 CM |
| Carton Weight | 22.4 KG |
Why choose us?
- Our company is a leading supplier of Cholesterol Checking Machine products and services in China.
- Our company adheres to product leadership and innovation, continues to develop Blood Lipid Test Strips and integrates industry operations, and strives to create longer-term value.
- Our company is a supplier and manufacturer of Cholesterol Checking Machine with competitive prices.
- We are aiming to become an enterprise that the society expects to exist, and we continue to accept new challenges.
- We are dedicated to providing our clients with exceptional Cholesterol Checking Machine products and services.
- Our company constantly absorbs and cites good technologies at home and abroad, pays attention to technological innovation, and transforms new technologies into high-quality products of enterprises and goes to the market.
- Our Cholesterol Checking Machine products are manufactured to meet the highest quality standards.
- Our core team has strong innovative thinking and operating ability with years of working experience in many fields.
- We are dedicated to providing our clients with the best possible value when they purchase our Cholesterol Checking Machine products.
- Facing the future market, relying on strong product R & D and production capacity, our company will continue to work closely with global dealer partners and all business units.
Hot Tags: Blood Lipid Test Strip, China Blood Lipid Test Strip manufacturers, suppliers